Twisted Single Pair PFA Insulated

Application

These cables are used with thermocouples for temperature measurements.

Specification

Conductor: Solid or stranded. Material is according to thermocouple type.

Insulation: PFA polymer

Screen: Aluminum tape

Drain wire: Tinned copper

Outer sheath: PFA polymer

Construction: Round

Color code: According to IEC 60584-3

K Type

AWG(mm Insulation Material Screen Material Sheath
Material
Max. Temp. (°C) Nominal O.D. (mm) Weight (kg/km)
24 (0.51) PFA Polymer Aluminum tape PFA Polymer 260 2.7 13.4
24 (7/0.2) PFA Polymer Aluminum tape PFA Polymer 260 2.9 13.8
20 (0.81) PFA Polymer Aluminum tape PFA Polymer 260 3.7 30.0
20 (7/0.32) PFA Polymer Aluminum tape PFA Polymer 260 3.8 30.3